THRESHOLD (MAT) SWITCH ADJUSTMENT (IF REQUIRED)
3. Measure distance from
upper edge of thresh-
old plate to vehicle oor
as shown in FIG. 60-3.
Distance should be
1/4” MAXIMUM at any
point across the width of
threshold plate.
LIFT AT GROUND LEVEL
FIG. 60-1
POWER SWITCH
THRESHOLD PLATE INSIDE SLOPE ANGLE 7.1°
FIG. 60-2
2. Set inside slope angle
of threshold plate to 7.1°
MAXIMUM as follows.
Center angle indica-
tor on the inside slope
of threshold plate (FIG.
60-2).
HEIGHT MEASUREMENT
(RH SIDE SHOWN)
FIG. 60-3
1/4”
1. Make sure power switch
is turned on. Lower Lift to
the ground (FIG. 60-1).
THRESHOLD
PLATE
VEHICLE
FLOOR
ANGLE
INDICATOR