Maxon WL7 Especificaciones Pagina 28

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 91
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 27
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
28
PATENTS PENDING
4. Loosen jam nut (FIG. 28-1B)
on the STOW switch adjust-
ment screw. Next, turn adjust-
ment screw counter-clockwise
(CCW) (FIG. 28-2) until con-
troller reads UNFOLD. Turn
adjustment screw clockwise
(CW) (FIG. 28-3) until con-
troller reads STOWED*. Then,
turn the adjustment screw 1/2
turn CW (FIG. 28-4).
6. When adjustment is complete, tighten
jam nut on the adjustment screw
(FIG. 28-1B).
5. Use the hand pendant to stow Lift
(FIG. 25-3). Make sure the platform
is stowed tightly. Repeat adjustment
steps 1 through 4 if necessary.
STOW SWITCH ADJUSTMENT
FIG. 28-1B
ADJUSTMENT
SCREW
LH TOWER
(LIFT WITH LH PUMP)
FIG. 28-1A
JAM NUT
LIFT TO
REMOVE
3. Remove cover from top of tower
(FIG. 28-1A).
7. Reinstall cover on tower (FIG. 28-1A).
COVER
ADJUST SO CONTROLLER READS “UNFOLD”
FIG. 28-2
CCW
CW
UNFOLD
STOWED*
+ 1/2-TURN CW
ADJUSTMENT SCREW
FIG. 28-4
ADJUST SO CONTROLLER READS “STOWED* ”
FIG. 28-3
STOW SWITCH ADJUSTMENT - Continued
Vista de pagina 27
1 2 ... 23 24 25 26 27 28 29 30 31 32 33 ... 90 91

Comentarios a estos manuales