PATENTS PENDING
6. Reconnect the high pressure hose
securely to elbow tting on cylin-
der (FIGS. 14-1A and 14-1B).
7. Clean up dripped or spilled hy-
draulic uid.
8. Repeat steps 3 through 7 for the
cylinder next to the pump.
RECONNECTING HP
HYDRAULIC HOSE
FIG. 14-1B
FIG. 14-1A
10. Pull out ller cap (FIG. 14-3). Fill the
reservoir with hydraulic uid (TABLE
14-1) to level shown on decal (FIG.
14-3). Reinstall ller cap (FIG. 14-3).
TABLE 14-1
RECOMMENDED HYDRAULIC FLUID
BRAND PART NUMBER
ROSEMEAD THS FLUID 17111
EXXON UNIVIS HVI 26
HYDRAULIC FLUID LEVEL
(LH PUMP SHOWN)
FIG. 14-3
NOTE: If the expected seasonal tem-
peratures are below 20°F, use
MIL-H-5606G hydraulic uid.
9. Raise and stow platform (FIG. 14-2).
11. Do the CHECKING HYDRAULIC FLUID
procedure in this manual.
STOWED PLATFORM
FIG. 14-2
CHANGING HYDRAULIC FLUID - Continued
RESERVOIR
FILLER CAP