Page 21
8.16 PS-21 Wiring Diagram
PS-21
OFF
E
-
+
TEMPERATURE SENSOR
#
- SUPPLY
+
#
TAPE OR CABLE TIE TEMPERATURE SENSOR TO NEGATIVE BATTERY TERMINAL (OR
AS CLOSE AS POSSIBLE). CONNECT BLACK STRIPED WIRE OF SENSOR TO R- OR B-
20 TO 60 VDC INPUT SUPPLY *
VA+
VA-
R+
R-
TS
B+
B-
+ SUPPLY
EARTH
*A NEGATIVE DC INPUT SUPPLY CAN BE USED. CONNECT THE MORE POSITIVE WIRE
(eg 0 V) TO +SUPPLY AND CONNECT THE MORE NEGATIVE WIRE (eg -48 V) TO -SUPPLY.
CAUTION! Connecting the
battery in reverse may cause
damage to the power supply.
-
+
24 VDC AUXILIARY OUTPUT (OPTIONAL)
13.8 VDC OUTPUT (FOR RADIO OR OTHER DEVICE)
-
-
+
BACKUP
BATTERY
GREY WITH BLACK STRIPE
8.17 PSU-3: Economy AC Input Power Supply (for PC-1)
+V and –V are wired to pins 7 and 8 (12V Supply Input) of the orange BL9 connector on the BA-4
backplane.
37.5
1 2 3 4 5
A
N
E
-V
+V
Voltage
Adjust
(13.8V)
+12V Supply Input
0V Supply Input
BA-4